IZ16E测量和显示系统增量式测量和可视化,无需接线
7 位数字 LCD 显示器,可显示符号和特殊字符电池状态和角度显示
通过嵌入式外壳轻松安装(与Z16兼容)
可选择显示模式:毫米、米、英寸(有分数显示)
可调计数方向
可调小数点和倍增因数
按键可锁定
可调参考值
增量式和绝对式测量之间切换
3个可调整的移位补偿量
可选2个外置输入,用于特殊字符,通过RJ45
可选2个外置输入,通过RJ45
可用接口:RS232 / RS485 / RF868 MHz
MECHANICAL DATA
Housing | norm panel housing |
Housing material | plastic, black |
Housing dimensions (W x H) | 96 x 72 mm |
Panel cut out (W x H) | 93 x 67 mm |
Keyboard | foil with short stroke keys |
Installation depth (complete) | min.30 mm, depends on version |
ELECTRICAL DATA
Display | 7 digit LCD (digit height 14 mm), with sign, battery status and measurement units |
Perspective | 12 o'clock |
Measurement units | mm / inch / m / ° |
Accuracy | ± 1 digit |
Power supply voltage | battery (1.5 V resp. 3 V), integrated or external. 24 V on request |
Current consumption | < 1 mA bei 1.5 V (with measuring system) |
Battery Service life | 1 ... 3 years (depending on battery type) |
External inputs | 2 x 5 ... 30 V (on request) |
External Outputs | 2 x 30 V open collector (on request) |
Optional interfaces | RS232 (SN100), RS485 (SN150), RF 868 MHz (SN600) |
Connections | fixed cable outlet, optional: round connector |
Data memory | Flash |
ENVIRONMENTAL CONDITIONS
Operating temperature | 0 ... +50 °C |
Storage temperature | -10 ... +60 °C |
Humidity | max. 80 %, non-condensing |
Protection class (front) | IP54 |
Protection class (rear) | IP40 |
MAGNETIC SENSOR
Type designation | MS-250 |
Dimensions (L x W x H) | 30 x 10 x 15 mm |
Measuring principle | magnetic, incremental |
Required magnetic tape | MB-20-25-10-1-R |
Magnetic tape pole pitch | 2.5 mm |
Distance sensor/ tape | max. 0.8 mm |
Resolution | 0.1 ... 0.01 mm |
Repeat accuracy | ±2 increments |
Operation speed | max. 4 m/s |
Housing material | zinc die cast |
Protection class | IP67 |
Connections | fixed connection with indicator or optionally with round connector |
Sensor cable | drag-chain suitable, 6-wire, twisted pairs and double-shielded |
Sensor cable length | 0.1 ... 2.0 m |
Sensor cable bending radius | min. 60 mm |
Weight | approx. 30 g |
Humidity | max. 95 %, non-condensing |
Influence of external magnetic fields | external magnetic fields > 1 mT, which directly impinge upon the sensor, can affect the system accuracy. |